prevent air draughts affecting the smoke/heat entering
the alarm. If the hole is too large or the alarm does
not seal it, it should be sealed with silicone rubber or
equivalent.
6. Replace the wiring cover. Check the alarm battery is
connected (Ei141RC/144RC/146RC only).
7. Carefully line up the unit on the base and slide on.
8. Press and hold the test/hush button for 10 seconds.
The horn will sound. On release of the test button the
local alarm will stop sounding immediately and the
interconnected Alarms will stop sounding a few seconds
later.
9. Connect the mains power to the alarm circuit. Check
the green light is on.
10. Attach the ‘Smoke Alarm’ identification label
provided to the distribution board to identify the alarm
circuit.
11. Attach the ‘Mains Smoke / Heat Alarms’ label
provided on or near the distribution board and write in
date installed and the number of alarms on the circuit.
Ensure the alarm operates correctly - see “TESTING &
MAINTAINING YOUR ALARM” section on page 4 of
the USER INSTRUCTIONS.
4.2 Interconnecting Alarms
Note: A maximum of twelve Ei141RC/144RC/146RC
/161RC /164RC/166RC Smoke or Heat Alarms may be
interconnected. Up to 8 additional accessories may also
be connected (see “ACCESSORIES” section).
If you wish to connect more than twelve alarms contact
your local distributor (see page 16 for details).
Systems using more than 3 or 4 alarms must be very
carefully planned to ensure nuisance/false alarms are
not excessive. e.g. from cooking fumes or steam. The
following is suggested:
Smoke Alarm Control Switch (model Ei1529RC)
should be incorporated into the system and be readily
accessible to all occupants so that the source of an
alarm can be quickly identified.
• All alarms must be cleaned and maintained regularly.
A qualified person must be on call to quickly remove
any nuisance units (i.e. units with red light flashing
rapidly) which are causing all the other alarms to
sound.
WARNING: Do not connect these Alarms to any
other type of Ei Alarm (apart from those listed
above) or to any other model produced by another
manufacturer. Doing so may damage the Alarms
and could result in a shock or fire hazard.
Wiring must be installed in compliance with local
regulations.